These are the models we stock for charging 3.2-3.4V nominal LiFePO4 cells: 1.5kW input plugs into any standard 10A power point. Two chargers can be used in parallel for 3kW and will plug into a 15A power point. Three chargers can be used with 3 phase power.
| MODEL NAME | Cells | Amps | Nom. V | Peak V | SLA Equiv. V |
| TCCH-08C-40A | 8 cells | 40A | 25.6V | 29.2V | 24V |
| TCCH-12C-30A | 12 cells | 30A | 38.4V | 43.8V | 36V |
| TCCH-16C-25A | 16 cells | 25A | 51.2V | 58.4V | 48V |
| TCCH-24C-16A | 24 cells | 16A | 76.8V | 87.6V | 72V |
| TCCH-30C-12A | 30 cells | 12A | 96V | 109.5V | 96V |
| TCCH-32C-12A | 32 cells | 12A | 100V | 109.5V | |
| TCCH-36C-10A | 36 cells | 10A | 108V | 109.5V | |
| TCCH-38C-10A | 38 cells | 10A | 121.6V | 138.7V | 120V |
| TCCH-45C-08A | 45 cells | 8A | 144.0V | 164.3V | 144V |
Charger output is isolated from the input so may be used in parallel or series.
For more information and ordering please contact us

These battery chargers are designed for charging LFP batteries in combination with the EV Power BMS. The TCCH 1.5kW series configured to EV Power specifications.
Features:
1. Internal integrated Power Factor Correction, no pollution to the electric network.
2. Wide input voltage range AC85V AC265VAC.
3. High efficiency 93% = lower energy bills. Non-PFC chargers are generally 80% efficient.
4. Fully-sealed and water-proof, protection class IP46. Internal shock resistance treatment, vibration-proof up to SAEJ1378 that can fully meet the standard of automobile usage.
5. BMS charge control interface for the EV Power BMS.
6. 12 Month Factory Warranty
Protection Features:
1. Thermal Self-Protection: When the internal temperature of he charger exceeds 75℃, the charging current will reduce automatically. If exceeds 85℃, the charger will shutdown protectively. When the internal temperature drops, it will resume charging automatically.
2. Short-circuit Protection: When the charger encounters an unexpected short circuit across the output, charging will automatically stop. When fault is removed, the charger will re-start in 10 seconds.
3. Reverse Polarity Protection: When the battery is polarity reversed, the charger will disconnect the internal circuit and the battery, the charging will stop and avoid been damaged.
4. Input Low-voltage Protection: When the input AC Voltage is lower than 85V, the charger will shutdown protectively and automatically resume working after the voltage is normal again.
Specifications:
- AC Input Voltage Range - AC85V AC265V
- Input power 1.5kW
- AC Input Frequency - 45 65 Hz
- AC Power Factor - ≥0.98
- Full Load Efficiency - ≥93%
- Mechanical Shock & Vibration Resistance Level - Conformance to SAEJ1378 Standard
- Environmental Enclosure - IP46
- Operating Temperature - -40℃~+55℃
- Storage Temperature - -40℃~+100℃
- Mechanical Dimensions(mm) - 352(L)×175(W)×139(H)
- Net Weight - 6.33kg
- C-Tick Australian Compliance - N22214